52
Automation API for CATC Bluetooth Analyzers
CATC Ver. 1.40
2.5.3 IRecOptions::SetRecMode
Sets the recording mode
Parameters
rec_mode - enumerated value providing the mode to set; ErecModes enumerator has
the following values:
RMODE_SNAPSHOT ( 0 ) – snapshot recording mode
RMODE_MANUAL ( 1 ) – manual trigger
RMODE_USE_TRG ( 2 ) – event trigger
Return values
E_INVALIDARG – invalid recording mode was specified
Remarks
The default setting of recording options is a snapshot recording mode.
Example
WSH:
CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName,
"\"))
Set Analyzer = WScript.CreateObject("CATC.Merlin")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetRecMode 2' Event trigger
C++:
HRESULT SetRecMode (
[in] ERecModes rec_mode );