QPHY-PCIE3-TxRx
Operators Manual
Revision B March, 2014
Relating to the following release versions:
Software Version Rev. 7.3.x.x
Script
PCI_Express_Test_Spec_Electrical_Layer_3_0_rev_0_9
Style Sheet Rev. 1.2
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - Revision B – March, 2014

QPHY-PCIE3-TxRx Operator’s Manual Revision B – March, 2014 Relating to the following release versions: Software Version Rev. 7.3.x.x Script

Strany 2

6 923662 Rev B General Setup The first sub-dialog contains general system settings. These remain in effect for each session, regardless of Stand

Strany 3 - Table of Contents

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 7 QualiPHY Test Process Once general system settings are in place, these are the steps for running

Strany 4 - About This Manual

8 923662 Rev B Run Reports The QualiPHY software automates report generation. On the framework dialog, go to General Setup > Report to pre-co

Strany 5 - Introduction

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 9 Customizing QualiPHY The pre-loaded configurations cannot be modified. However, you can create yo

Strany 6

10 923662 Rev B Edit Variables The Variable Setup tab contains a list of test variables. See QPHY-PCIE3-TxRx Variables for a description of each

Strany 7 - Installation and Setup

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 11 Edit Test Limits The Limits tab shows the Limit Set currently associated with the configuration.

Strany 8 - Set Up Remote Control

12 923662 Rev B X-Replay Mode The X-Replay mode window is an advanced (“developer”) view of QualiPHY. The tree in the upper-left frame enables y

Strany 9 - Using QualiPHY

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 13 QPHY-PCIE3-TxRx Testing Test Preparation Before beginning any test or data acquisition, the osci

Strany 10 - General Setup

14 923662 Rev B Add-in Card Rx This configuration includes two steps. Step 1 is to perform Rx calibration of the PeRT3 Phoenix by using the CBB

Strany 11 - QualiPHY Test Process

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 15 Figure 7 – Step 1 setup for Differential Mode Noise, Eye height and Eye Width Calibration. Fig

Strany 12 - 923662 Rev B

700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com © 2014 Teledyne LeCroy, Inc.

Strany 13 - Customizing QualiPHY

16 923662 Rev B Add-in Card Tx This configuration will run the Add-in Card Tx compliance tests using the CBB3 fixture. Tx Compliance tests are p

Strany 14

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 17 A toggle switch on the CLB controls the clock to Rx lane0. Every time the switch is pressed, J5/

Strany 15 - Edit Test Limits

18 923662 Rev B Figure 11 – Example of Signal Test dialog and Signal Test results. System Rx This configuration includes two steps. Step 1 is t

Strany 16 - X-Replay Mode

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 19 System Tx This configuration will set up for System Tx compliance testing using the CLB3. Predef

Strany 17 - QPHY-PCIE3-TxRx Testing

20 923662 Rev B QPHY-PCIE3-TxRx Variables DEMO MODE This variable allows you to run the tests in demo mode. When this value is Yes, the tests ca

Strany 18

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 21 TEST MODE This variable can be set to “AquireNewData” or “UseSavedData”. For RX calibration, thi

Strany 19 - 923662 Rev B 15

22 923662 Rev B TESTTYPE [COMPLIANCE|95% CONFIDENCE] The Compliance setting uses 2 minutes and 5 seconds (1e12 bits) limit with 0 or 1 error fo

Strany 20

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 23 Manual Deskewing Procedures This section is only applicable to the oscilloscope and the cables c

Strany 21 - 923662 Rev B 17

24 923662 Rev B  Trigger i. Configure to Source to be FastEdge. ii. Set the Slope to Positive.  Parameter Measurements: i. Set the source f

Strany 22

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 25 10. Save Channel X to M1.  Click File  Save Waveform.  Set Save To Memory.  Set the Sourc

Strany 23 - System Tx

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B i Table of Contents Introduction ...

Strany 24 - QPHY-PCIE3-TxRx Variables

26 923662 Rev B Cable Deskewing Without Using the Fast Edge Output The following procedure demonstrates how to manually deskew two oscilloscope

Strany 25 - 923662 Rev B 21

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 27 In the previous procedure, we used the default setup of the Skew parameter (which is detecting p

Strany 27 - Manual Deskewing Procedures

ii 923662 Rev B Table of Figures Figure 1 - QualiPHY framework dialog and Standard selection menu. ...

Strany 28

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 1 Introduction About QualiPHY QualiPHY is highly automated compliance test software meant to help y

Strany 29 - 923662 Rev B 25

2 923662 Rev B Required Host Computer System Usually, the oscilloscope is the host computer for the QualiPHY software, and all models that meet

Strany 30

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 3 Installation and Setup QualiPHY is a Windows-based application that can be configured with one or

Strany 31 - Error Messages

4 923662 Rev B Set Up Dual Monitor Display Teledyne LeCroy recommends running QualiPHY on an oscilloscope equipped with Dual Monitor Display cap

Strany 32

QPHY-PCIE3-TxRx Operator’s Manual 923662 Rev B 5 Using QualiPHY This section provides an overview of the QualiPHY user interface and general proc