Serial Data Debug Solutions
919586 RevA
BRIEF LP TIMING TEST DESCRIPTIONS
With LP Timing selected in the Category field, the following Measure values are available:
TLP-PER-Data-500, TLP-PER-Data-930, TLP-PULSE-Data-500, TLP-PULSE-Data-930, FIRST-TLP-PULSE-Data-
500, FIRST-TLP-PULSE-Data-930, LAST-TLP-PULSE-Data-500, and LAST-TLP-PULSE-Data-930.
Name
Purpose
TLP-PER-Data-500
To verify that the period (TLP-PER-TX) of the DUT’s Data Lane LP transmitter
XOR Clock is within the conformance limits.
TLP-PER-Data-930
TLP-PULSE-Data-500
To verify that the pulse width (TLP-PULSE-TX) of the DUT’s Data Lane LP
transmitter XOR Clock is within the conformance limits.
TLP-PULSE-Data-930
FIRST-TLP-PULSE-Data-500
FIRST-TLP-PULSE-Data-930
LAST-TLP-PULSE-Data-500
LAST-TLP-PULSE-Data-930
BRIEF LP SLEW RATE TEST DESCRIPTIONS
With LP Slew Rate selected in the Category field, the following Measure values are available:
SR-MAX-Dp, SR-MAX-Dn, SR-MAX-CLKp, SR-MAX-CLKn, SR-FALL-MIN-Dp, SR-FALL-MIN-Dn, SR-FALL-
MIN-CLKp, SR-FALL-MIN-CLKn, SR-RISE-400-700-MIN-Dp, SR-RISE-400-700-MIN-Dn, SR-RISE-400-700-
MIN-CLKp, SR-RISE-400-700-MIN-CLKn, SR-RISE-700-930-MIN-Dp, SR-RISE-700-930-MIN-Dn, SR-RISE-
700-930-MIN-CLKp, and SSR-RISE-700-930-MIN-CLKn.
Name
Purpose
SR-MAX-Dp
To verify that the Slew Rate (δV/δtSR) of the DUT’s Data & Clock Lanes LP
transmitter is within the conformance limits, for specific capacitive loading
conditions.
SR-MAX-Dn
SR-MAX-CLKp
SR-MAX-CLKn
SR-FALL-MIN-Dp
SR-FALL-MIN-Dn
SR-FALL-MIN-CLKp
SR-FALL-MIN-CLKn
SR-RISE-400-700-MIN-Dp
SR-RISE-400-700-MIN-Dn
SR-RISE-400-700-MIN-CLKp
SR-RISE-400-700-MIN-CLKn
SR-RISE-700-930-MIN-Dp
SR-RISE-700-930-MIN-Dn
Zobrazit stránku 137