Chapter 8: Recording Options PETracer ML User Manual
136 Teledyne LeCroy
Example 5
Result: Only TLP (any type) is in the CATC Trace.
Reason: The sequence rule to filter in TLP:Completion is not contradicting the global
state rule to filter in Any TLP. Both rules are applied.
Example 6
Result: Only TLP (any type) is in the CATC Trace.
Reason: The sequence rule to filter in Any TLP is not contradicting the global state rule
to filter in TLP:Completion. Both rules are applied.
Example 7
Result: All TLP are filtered out.
Reason: The sequence rule to filter out Any TLP is not contradicting the global state rule
to filter out TLP:Completion. Both rules are applied.