LeCroy Corporation Target and Device Emulation
170
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
4. Click the down arrow on the ClOSEPrimitive or DONEPrimitivedropdown list box
in the CloseConnectionSettings dialog, then choose a Close or Done Primitive.
5. Enter a value in the CLOSE/BREAKPrimitiveCount text box.
SAS Commands Errors (SAS only)
Click the SASCommandsicon in the Errors window to display the
Commands Error Setting dialog.
Figure 2.177: SAS: SAS Commands Error Setting Dialog
1. Click the SSP,SMPor Taskoption button to display the commands available for each
of these categories in the Event Selection window.
2. Click a command for which to set an error, check the GenerateErrorwhen:check
box, then enter values for LBA,TAG, or Commandnumberin the corresponding text
box.
Commandnumber specifies the number of the command for which you want to
inject error. For example, if you select the Inquiry command, then enter 2 for the
Command Number, you inject error on the 2nd Inquiry command.
Numberoferrorcommands specifies the number of commands for which you want
to inject error. For example, if you select the Inquiry command, then enter 2 for the
Command Number, and enter 3 for Number of Error Commands, the target
emulator injects error on the 2, 3, and 4 Inquiry commands, because you want to
inject on 2nd command and continue error injection as much as 3 times.
When using Command Number as the Error Injection filter, you can repeat the
erring‐command sets by checking Repeaterror. The default value is 1, which injects
error only once, with no repeats. In the above example, the system injects error on
the 2, 3, and 4 Inquiry commands and does not inject error for other commands.
If you enter 2 for Repeat Error, the system injects error on the 2nd, 3rd, 4th, 6th,
Komentáře k této Příručce