 Sierra M64 SAS/SATA Protocol Analyzer User Manual 173
Target and Device Emulation
LeCroy Corporation
Insert Frame
Check Insert Frame, click the down arrow on the Type combo box, and choose the frame
type. Make sure that you have clicked More.
Incoming Frame Settings
Before selecting Incoming Frame Settings, select the TypesOfFrames and the
FrameNumber on which to inject an error. Then check IncomingFrame in the Generate
Error On area and then the enabled Settings button to display the Incoming Frame
Settings dialog.
Figure 2.179: Incoming Frame Setting Dialog
Handshake Error
Check Handshake Errors to enable selection of error on handshake. Check NAK, CRC, or
any other Primitive to send as an incoming frame response. Check No Handshake to send
no response.
Defer Handshake Errors
Check DeferHandshake and enter a value for the time to defer the handshake.